As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK CARGO COMPARTMENT, UPPER DECK CARGO DOOR LOWER SILL SPOOL FITTING NR 2 FASTENER HOLES FOUND WITH CRACK INDICATION AT HOLE 'C' AND 'D' DURING OPEN HOLE HFEC INSPECTION. MAIN DECK CARGO COMPARTMENT, UPPER DECK CARGO DOOR LOWER SILL SPOOL FITTING NR 2 CARRIED OUT BUSHING REPAIR AS PER SRM 53-50-00 VOL I FIG 10. REPAIR CLASSIFIED MAJOR AS PER FEDEX GMM 6-2-100.