What was found
DURING OPEN-HOLE HFEC INSPECTION ON 0.460" HOLES, MAIN CARGO DOOR LOWER JAMB SUPPORT FITTING NR 1 FOUND WITH CRACK INDICATIONS AT HOLES A, B, C AND D. MAIN CARGO DOOR JAMB NR 1 FITTING REMOVED AND REPLACED AS PER SRM 51-33-01, VOL II. THIS REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.