What was found
MAIN DECK LAV FLOOR WEB PANEL, UPPER LWR SURFACES ARE CORRODED BS 304 - 340, RBL 40 - 60, WL 208. REMOVED CORROSION, ORIGINAL MATERIAL THICKNESS .042 INCH, REMAINING .035', REMOVED .007. FOUND TO BE OUT OF LIMITS REF DRM 53-10-1 PG 2, TOOL ID AAR 9800 CAL DUE 6-28-09. CUT DRAIN OPENINGS IN NEW PANEL, TREATED AND PRIMED, REF SRMM 51-10-2 PG 2, FED EX GMM 7-0-1001 PG 1. THIS IS CLASSIFIED AS A MINOR REPAIR.