What was found
FLOORBOARD SUPPORT NUTPLATES RUSTED STA 305-312 RBL 55 FWD LAV. REMOVED FLOOR SUPPORT ANGLE, REMOVED CORROSION, FOUND TO BE OUT OF LIMITS ORIG MATERIAL THICKNESS .040, REMAINING .033, REMOVED .007. INSTALLED NEW ANGLE REF SRM 51-30-2 PG 2, SRM 53-10-1 PG 1, BOEING DWG 65-17593-151, TOOL ID AAR 9800 CAL DUE DATE 6/24/09. THIS IS CLASSIFIED AS A MINOR REPAIR.