What was found
CRACK INDICATION FOUND DURING HFEC OPEN HOLE INSPECTION ON EXISTING 0.460 INCH HOLES AT MAIN CARGO DOOR LOWER JAMB NR 6 SUPPORT FITTING AT HOLES A, B, C AND D. MAIN CARGO DOOR LOWER JAMB NR 6 SUPPORT FITTING AT HOLES A, B, C AND D BUSHING REPAIR CARRIED OUT AS PER SRM 53-50-00 FIG. 10 VOL. 1. SUPPORT FITTING REMOVED AND REPLACED AS PER SRM 51-33-01 VOL. II. REPAIR CLASSIFIED AS MAJOR AS PER FEDEX GMM 6- 2-100.