As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CARGO DECK FLOOR SUPPORT HAS CORROSION 4 INCH AFT OF FRAME 13; LBL 31 INCHES. REMOVED CORROSION IAW SRM 51-74-10. ORIGINAL MATERIAL THICKNESS 0.079. MATERIAL REMOVED 0.013. MATERIAL REMAINING 0.066. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-00. REMOVED FLOOR SUPPORT IAW SRM 51-40-21; PG 6. LOCATED AND DRILLED THE HOLES IAW IAW SRM 51-40-44 AND 51-40-12. INSTALLED FLOOR SUPPORT IAW SRM 51-40-21; PG 6. APPLIED CIC IAW AMM 51-22-00.