What was found
DURING INSP OF HORIZ STAB UPPER AND LOWER CONSTANT SECTION SKIN PLANK FLANGE, FOUND 4 PANEL WITH CRACK IN FLYABLE LIMIT, P/N 7208-1, P/N 7207-1, P/N 7205-1, P/N 7204-1, SEE ATTACHED INSPECTION FINDING FORM. REPAIRED AREA IAW EA NR 8-5510-120477.