As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME DAMAGED STA 360 STR 2R. CUTOUT DAMAGED AREA DIMS 1 1/8 INCH BY 1 INCH, FABRICATED REPAIR ANGLE FROM 7075-0 .063 PO NR 9007470 DIMS 9 INCH BY 3 INCH BY 1 INCH. INSTALLED REPAIR ANGLE AT BS 360 STR 2R IAW B727 SRM 53-10-4 FIG 2 AND SRM 53-10-2 FIG 3.