CORROSION FOUND ON FLOORBEAM AT STA 365, RBL 3 TO RBL 51. EVALUATE AND RECTIFY. REPAIR CARRIED OUT ON FLOORBEAM UPPER CHORD AT STATION 365 BETWEEN RBL 3 AND RBL 51 IN ACCORDANCE WITH B 757-200 SRM 53-00-51 FIGURE 201 REPAIR 1, REVISION 93. REPAIR IS CLASSIFIED AS MAJOR AS PER GMM 6-02-100 CRITERIA.