What was found
NR 1 ENG COMPRESSOR STALL BEGINNING DESCENT FROM FL350 ENG WOULD NOT RESTART. WINDMILLING WITHOUT OIL PRESSURE WAS 15 MINUTES. REMOVED AND REPLACED THE STATOR VANE ACTUATOR .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 ENG COMPRESSOR STALL BEGINNING DESCENT FROM FL350 ENG WOULD NOT RESTART. WINDMILLING WITHOUT OIL PRESSURE WAS 15 MINUTES. REMOVED AND REPLACED THE STATOR VANE ACTUATOR .