What was found
DENT LT AFT FUSELAGE STA 1070 S18-20L. EVALUATED DENT AT STA 1070 STR 18L TO 20L AND FOUND WITHIN LIMITS IAW SRM 53-30-01 FIG1 BUT DENT CROSSES OVER STR 19L EA 7-5330-117024 "SKIN PANEL DENT AT STA 1074 S18-20L" ISSUED TO ADDRESS DENT CROSSING S19L. PER EA 7-5330-117024 SUBJECT AREA REMAINS CAPABLE OF CARRYING DESIGN LOADS AND WILL HAVE NO ADVERSE AFFECT ON SKIN FATIGUE LIFE. HFEC INSPECTED AREA AND FOUND NO CRACKS IN THE DENT LOCATIONS.