What was found
FOUND CORROSION ON RUN OUT FITTING C16-17, P 44 RT OUT OF LIMIT. REPAIR PERFORMED IAW SRM 53-12-14 FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON RUN OUT FITTING C16-17, P 44 RT OUT OF LIMIT. REPAIR PERFORMED IAW SRM 53-12-14 FIG 201.