What was found
FOUND DAMAGED HOLES DURING ACCOMPLISHMENT OF SB A300-57-6086 (HOLE G,T) ON HORIZONTAL FLANGE, C47, RT. REPAIR PERFORMED BY OVERSIZING THE HOLES, NDT FOR DAMAGE FREE CONDITION AND INSTALLING A CONICAL WASHER IN HOLE T IAW RAS/70512903/024/2008 ISS A, APPROVED BY EA 6-5710-123133.