As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD MAIN ENTRY DOOR FUSELAGE CUTOUT, SILL WEB HAS NUMEROUS GOUGES, UPPER SURFACE BS 320 LBL 64, BLENDED GOUGES GENERATED EA FOR BLEND ALLOWANCE, BLEND IS WITHIN LIMITS REF EA7-5310-123801 TREATED AND PRIMED REF EA 7-5310-123801 THIS IS CLASSSIFIED AS A MINOR REPAIR.