What was found
MAIN CABIN FLOORBEAM, BS 1320, RBL 12-25, HAS CORROSION. REPAIRED MAIN CABIN FLOORBEAM, BS 1320, RBL 12-25, IAW SRM 53-00-51. CORROSION WAS DETERMINED TO BE OUT OF LIMITS PER SRM 53-00-51. THIS REPAIR IS CLASSIFIED AS A CATEGORY "A" MAJOR REPAIR WITH NO FOLLOW UP TRACKING REQUIREMENTS.