What was found
FWD LOWER CARGO BAY, DOOR THRESHOLD WRAP AROUND SCUFF PLATE CRACKED IN SEVERAL AREAS REMOVED THRESHOLD REF SRM 51-30-2, WELDED CRACKS REF DWG SR27-53-025 REV.C ON N/R N00383. INSTALLED THRESHOLD REF SRM 51-30-2 PG 2-14 THIS IS CLASSIFIED AS A MINOR REPAIR.