What was found
MAIN DECK CARGO COMPARTMENT, LT SIDEWALL STRUCTURE FRAME BS 1701 FOUND DENTED, LONGERON 12L. MAIN DECK CARGO BAY, LT SIDEWALL STRUCTURE FRAME BS 1701 AT L-12L, DENTED AREA REPAIRED AS PER SRM 53-30-00 FIG. 1 VOL. I. REPETITIVE INSPECTION REQUIRED - INITIAL INSPECTION AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-30-00. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.