What was found
04 FASTENER HOLES FOUND CRACK INDICATION DURING OPEN HOLE HFEC INSPECTION AT RIGHT WING LOWER SKIN ACCESS DOOR CUT OUT BETWEEN STA XORS = 690 AND STA XORS = 700. RIGHT WING LOWER SKIN ACCESS DOOR CUT OUT BETWEEN STA XORS = 690 AND STA XORS = 700, 04 FASTENER HOLES CARRIED OUT REPAIR AS PER EA NR 1-5710-122605 PART 1. TITLE, AD 2007-07-04, WINGS, RIGHT LOWER SKIN PLANK CUT OUT AT 636AB, FOUR ACCESS DOOR ATTACHMENT BORES WITH CRACK INDICATIONS PSE 57.23.01 ALI - REPAIR. THIS REPAIR CLASSIFIED AS MINOR AS PER GMM 6-2-100.