What was found
AFT PIT BS 1130 FRAME UPPER CHORD HAS DOUBLE DRILLLED HOLE IB OF TIE DOWN FITTING AT S27L. REMOVED AND INSTALLED FLOOR SUPPORT BRACKET, TIE DOWN BRACKET, FLOOR SUPPORT REF 51-30-2. REPAIRED DAMAGED FRAME REF SRM 51-40-3 FIG 1. TREATED AND PRIMED REF SRM 51-10-2 THIS IS CLASSIFIED AS A MAJOR REPAIR.