What was found
AFT PIT BS 1130 FRAME UPPER CHORD HAS TRIPLE DRILLED HOLE INBD OF TIE DOWN FITTING AT S27R. CUTOUT DAMAGE, REMOVED FASTENERS FROM FRAME AT REPAIR AREA. FABRICATED REPAIR ANGLE & HEAT TREATED TO T6 CONDITION. TREATED, PRIMED, & INSTALLED FRAME REPAIR ANGLE. REF: SRM 51-40-3, FIG. 1 / SRM 51-30-2, PG. 8 / SRM 51-10-2, PG. 1-2 / SHOP REPAIR NON ROUTINE CARD NO. N00953. THIS IS CLASSIFIED AS A MAJR REPAIR