What was found
AFT PIT BS 1090 FRAME HAS DOUBLE DRILLED HOLE INBD OF TIEDOWN FITTING AT S27R. REPAIRED IAW SRM 51-40-3. FABRCATED BRACKET IAW DWG 69-44106 TREATED, PRIMED IAW SRM 51-10-2. THIS CLASSIFIED AS A MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT BS 1090 FRAME HAS DOUBLE DRILLED HOLE INBD OF TIEDOWN FITTING AT S27R. REPAIRED IAW SRM 51-40-3. FABRCATED BRACKET IAW DWG 69-44106 TREATED, PRIMED IAW SRM 51-10-2. THIS CLASSIFIED AS A MAJOR REPAIR.