What was found
FWD PIT BS 620 FRAME CRACKED RBL 2 TO RBL 3 WL 155, BELOW FLOOR SUPPORT. REPAIRED IAW SRM 51-40-3. THIS IS CLASSIFIED AS A MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT BS 620 FRAME CRACKED RBL 2 TO RBL 3 WL 155, BELOW FLOOR SUPPORT. REPAIRED IAW SRM 51-40-3. THIS IS CLASSIFIED AS A MAJOR REPAIR.