As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
UPPER LOBE INTERIOR STATION 760 RIGHT, BELOW WINDOW AT DOOR CUTOUT, CILL LINER ATTACH BRACKET IS CRACKED. REMOVED CRACKED BRACKET VERIFIED MATERIAL FOR BRACKET AND FABRICATED NEW BRACKET. TREATED AND PRIMED INSTALLED NEW BRACKET IDENTIFIED P/N ON BRACKET IN REF TO GMM 7-0-1000 PG 2 SRM 51-30-2 PG 1-13 AND DWG BY 25FX1432. THIS IS CLASSIFIED AS A MINOR REPAIR.