As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CARGO DECK HAS GOUGE ON FRAME SPLICE AT FR 29 3.5 INCH BELOW STR 12. REMOVED AND REPLACED FRAME SPLICE IAW SRM 51-40-21, LOCATED AND DRILLED IAW SRM 51-40-44. TREATED AND PRIMED IAW SRM 51-21-10. SPLICE FABRICATED ON TRAVELER T8/765592.