As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CARGO DECK HAS GOUGE ON FRAME SPLICE 2.5 INCH BELOW STR 12 L ON FR 32. REMOVED AND REPLACED FRAME SPLICE IAW SRM 51-40-21, LOCATED AND DRILLED IAW SRM 51-40-45. TREATED AND PRIMED IAW SRM 51-21-10. FABRICATED NEW SPLICE ON TRAVELER T8/765595.