What was found
FWD PIT LEFT SIDE FRAME, BS 520 AT STR 24L , UPPER FLANGE HAS 2 EA.DENTS WITIN 3". INSTALLED FRAME REPAIR AFTER REMOVING DAMAGE FROM FRAME. (CLASSIFIED AS A MAJOR REPAIR) REF SRM 51-40-06 PG 1-6 2 EA. DENTS REMOVED BY CUTOUT. FABRICATED NEW FRAME REPAIR, ALODINE, PRIMED PART. INSTALLED REPAIR AS REQUIRED. NO OTHER DEFECTS NOTED THIS IS CLASSIFIED AS A MAJOR REPAIR