What was found
MAIN DECK FLOOR E/E RACK STANTION SUPPORT INTERCOSTAL VERT FLANGE IS CRACKED BS 371 RBL 2 WL 199. REMOVED ANGLE VERIFIED MATERIAL ID FABRICATED NEW ANGLE INSTALLED NEW ANGLE AND WIRE BUNDLE CLAMP, REF SRM 51-30-2 PG 2, REF DWR 65-24297, REF MM 51-20-151 PG 1- 6, REF SRM 51-30-2 PG 8, 13-14. THIS IS CLASSIFIED AS A MINOR REPAIR.