What was found
UPPER LOBE INTERIOR STATION 760 TO 850 RBL 45 INCH, 24' FLOOR BOARD ATTACH ANGLE HAS WEAR IN SEVERAL AREAS. REMOVED NUT PLATE 8 SRM 51-30-02, BLENDED WEAR MARKS STA 760 - 850 RBL 24 REF SRM 51-10-1 ORIG "T'' .088, WORST "T" REMOVED .035 INCH. REMAINING "T' .053 INCH STA 808 RBL 24, OUT OF LIMITS. REPAIR REF EA 7-5310-118309, STA 760 - 850 RBL45 WEAR MARKS THROUGH PAINT, CLEANED, TREATED AND PRIMED REF MM 20 151 7. TREATED AND PRIMED STA 760 - 802/817 - 850 RBL 24 SOPM 20-43-05, SOPM 20-44-04, HFEC PER EA 7-5310-118309 STEP 3 PART. NO CRACKS DECTECTED, ROTO PEENED STA 808-RBL 24. TREATED AND PRIMED, FILLED BLEND WITH SEALANT APPLIED CORROSION INHIBITOR REF EA NR 7-5310-118309 PG 2 ITEM 3-7.