What was found
MAIN CARGO DECK FR 59 BENT BELOW STR 13L 2 INCH TO 4 INCH. REWORKED THE UPPER FLANGE SECTION IAW SRM 51-26-00, PERFORMED HFEC INSPECTION IAW NTM 51-10-08 PT 6. NO CRACK INDICATIONS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CARGO DECK FR 59 BENT BELOW STR 13L 2 INCH TO 4 INCH. REWORKED THE UPPER FLANGE SECTION IAW SRM 51-26-00, PERFORMED HFEC INSPECTION IAW NTM 51-10-08 PT 6. NO CRACK INDICATIONS NOTED.