What was found
PASSENGER CABIN FLOOR WEB BS 1110 - 1130 LBL 69 FWD OUTBOARD FASTENER HAS CORROSION AROUND IT FABRICATED NEW FLOOR WEB IAW DWG 65-22735-35. INSTALLED NEW FLOOR WEB IAW SRM 51-30-02 PG 5. THIS IS CLASSIFIED AS A MINOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PASSENGER CABIN FLOOR WEB BS 1110 - 1130 LBL 69 FWD OUTBOARD FASTENER HAS CORROSION AROUND IT FABRICATED NEW FLOOR WEB IAW DWG 65-22735-35. INSTALLED NEW FLOOR WEB IAW SRM 51-30-02 PG 5. THIS IS CLASSIFIED AS A MINOR REPAIR.