What was found
MAIN CARGO DECK HAS GOUGE ON FRAME 54 3 INCHES BELOW STR 12R. BLENDED AREA IAW SRM 51-73-10, FOUND WITHIN LIMITS. HFEC IAW SRM 51-10-08 PT6, NO CRACKS FOUND. TREATED AND PRIMED IAW SRM 51-23-20.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CARGO DECK HAS GOUGE ON FRAME 54 3 INCHES BELOW STR 12R. BLENDED AREA IAW SRM 51-73-10, FOUND WITHIN LIMITS. HFEC IAW SRM 51-10-08 PT6, NO CRACKS FOUND. TREATED AND PRIMED IAW SRM 51-23-20.