What was found
FOUND AFT PIT FRAME REPAIR LOCATED AT APPROX BS 1050 STR S-27L TO 26L. REPAIR REQUIRES EVALUATION FOR MAJOR/MINOR DETERMINATION AND IF THE REPAIR WAS ACCOMPLISHED USING FAA APPROVED DATA EVALUATION DETERMINED INSUFFICIENT FASTENERS. REMOVED REPAIR SRM 51-30-2, VERIFIED MATERIAL FOR REPLACEMENT AND FABRICATED REPLACEMENT REF DWR 65-16343 A35227 PO 1041113. HEAT TREATED NR 8130 2008-11-08. DRILLED AND FINAL TRIM DOUBLER REF SRM 51-30-3 FIG 1. TREATED AND PRIMED PARTS REF SRM 51-10-2. INSTALLED DOUBLER REF SRM 51-70-3. FAB REPAIR ANGLE REF DWR 65-67276-50 MATERIAL A 66622 PO 1008655 INSTALLED REPAIR ANGLE SRM 51-30-6. THIS IS CLASSIFIED AS A MAJOR REPAIR.