What was found
UPON EXTENSION OF LANDING GEAR, IMMEDIATELY GOT 3 GREEN INDICATORS, THEN THE LIGHTS WENT OUT. FOUND M-5 C/B TRIPPED. OBSERVED SMOKE RISING FROM BEHIND LANDING GEAR PANEL, AND SMELLED BURNT INSULATION. REMOVED AND REPLACED LANDING GEAR PANEL, OPS CHECK GOOD.