What was found
FOUND UPPER FLOORBEAM 41 IS CORRODED. CORROSION REMOVED AND FOUND TO BE BEYOND MANUFACTURERS LIMITS. REMOVED AND INSTALLED FLOORBEAM IN ACCORDANCE WITH SRM 51-25-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND UPPER FLOORBEAM 41 IS CORRODED. CORROSION REMOVED AND FOUND TO BE BEYOND MANUFACTURERS LIMITS. REMOVED AND INSTALLED FLOORBEAM IN ACCORDANCE WITH SRM 51-25-01.