What was found
DURING NDT INSPECTION, CRACK INDICATION NOTED ON THE L/H SIDE AT WS178.00, FLAP HINGE BOX ATTACHMENT FITTING ON THE I/B FWD HOLE ON THE INTERNAL RIB SIDE. PERFORMED PERMANENT REPAIR IN ACCORDANCE WITH RFTS-129840 REV. 0, DATED JULY 28, 2026, AND MHI RJ REO 670-57-21-1144 REV. --, DATED JULY 28, 2026.