Service difficulty report · Life Vest

Difficulty date
February 25, 2000
Submitted
March 31, 2000
Operation
General aviation
System (JASC)
2561 · Life Jacket
Part
Life Vest
Condition
Failed
Location
Cabin
Component
Life Vest · Eaaeromarine
Component part number
KSE35HC2L8
Stage of operation
IN
How discovered
V
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHILE ATTEMPTING TO INFLATE THIS DUAL CELL ADULT LIFE PRESERVER, BOTH TOGGLES WERE PULLED SIMULTANEOUSLY. THE BACK CELL INFLATED CORRECTLY, THE FRONT CELL FAILED TO INFLATE DUE TO THE ACTUATING LEVER PULLING OUT OF INFLATOR ASSEMBLY HOUSING ALLOWING INFLATOR PIN AND SPRING TO FALL OUT OF ASSEMBLY WITHOUT BREAKING SEAL ON CO2 CARTRIDGE. DISASSEMBLY OF BOTH THE GOOD AND FAILED INFLATOR ASSEMBLIES AND COMPARISON OF THE 2 ACTUATING ARM RETAINER PINS SHOWED THE FAILED ASSEMBLY PIN WAS APPROX 0.092 INCH SHORTER THAN THE RETAINER PIN OUT OF THE GOOD ASSY. NOTE THAT BOTH OF THESE PINS ARE STEEL. THIS VEST IS NOT AFFECTED BY EAM SB SBV-25-2 BY DATE OF MFG AND HAVING STEEL PINS. (X)