What was found
FOUND DURING SCHEDULED B-CHECK SERVICE CHECK AND ''G9'' BULKHEAD INSTALLATION, CABIN FLOORBEAM BS 344 UPER CAP HAS ELONGATED HOLES. SUBMITTER STATED HOLES MISDRILLED DURING PREVIOUS MODIFICATION. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND DURING SCHEDULED B-CHECK SERVICE CHECK AND ''G9'' BULKHEAD INSTALLATION, CABIN FLOORBEAM BS 344 UPER CAP HAS ELONGATED HOLES. SUBMITTER STATED HOLES MISDRILLED DURING PREVIOUS MODIFICATION. (X)