What was found
FOUND .4374 INCH CRACK THROUGH FASTENER HOLE AT RIGHT OUTBOARD FOREFLAP LEADING EDGE ABOVE NR 7 FLAP TRACK AREA. STOP DRILLED CRACK IAW SRM 51-10-1 PAGE 1. FABRICATED COUPLER REPAIR IAW 57-50-4 PAGE 17. HFEC INSPECTION OF CUTOUT CONFIRMED NO CRACKS. FABRICATED NEW LEADING AREA IAW 57-50-4 PAGE 9. INSTALLED REPAIR PARTS IAW 51-10-2 AND 51-30-00. (M)