As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN FLOORBEAM STATION 320 LBL 46 HAS CORROSION AT ANCHOR NOT. REMOVED CORROSION IAW 51-10-6 PAGE 12. ACCOMPLISHED UT THICKNESS CHECK FOUND OUT OF LIMITS. CUT OUT DAMAGED AREA IAW 53-10-8 PAGE 49. FABRICATED ANGLES AND SPLICE, INSTALLED, TREATED IAW 53-10-2 FIG 9. (M)