What was found
FOUND CABIN FLOOR SUPPORT INTERCOSTAL WEB HAS APPROX .25 INCH CRACK AT FORWARD END JUST AFT OF BS 400 BL 0. REMOVED INTERCOSTAL WEB. FABRICATED AND INSTALLED NEW WEB IAW SRM 51-30-2 PAGE 2, 51-10-1 PAGE 4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CABIN FLOOR SUPPORT INTERCOSTAL WEB HAS APPROX .25 INCH CRACK AT FORWARD END JUST AFT OF BS 400 BL 0. REMOVED INTERCOSTAL WEB. FABRICATED AND INSTALLED NEW WEB IAW SRM 51-30-2 PAGE 2, 51-10-1 PAGE 4. (M)