What was found
FOUND CABIN FLOORBEAM STATION 1030 LBL 25 THROUGH RBL 25 HAS CORROSION. REMOVED CORROSION, OUT OF LIMITS. FABRICATE ANGLE REPAIR AND STRAP IAW SRM 51-40-2 PAGE 6, 51-10-6 PAGE 12. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CABIN FLOORBEAM STATION 1030 LBL 25 THROUGH RBL 25 HAS CORROSION. REMOVED CORROSION, OUT OF LIMITS. FABRICATE ANGLE REPAIR AND STRAP IAW SRM 51-40-2 PAGE 6, 51-10-6 PAGE 12. (M)