Service difficulty report · Life Raft

Difficulty date
April 27, 2000
Submitted
May 22, 2000
Operation
General aviation
System (JASC)
2564 · Life Raft
Part
Life Raft
Part number
FR46
Part serial
J31
Condition
Failed
Location
Safety Equipment
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING SCHEDULED MAINTENANCE, LIFE RAFT FUNCTIONALLY TESTED. THE INFLATABLE TUBE NR 1 FAILED TO INFLATE PROPERLY. FURTHER INVEST, REVEALED THE ASPIRATOR''S AIRFLOW BECAME BLOCKED WITH ITS OWN ANTI-CHAFING COATING FOR THE OUTLET. THIS COATING IS NORMALLY APPLIED DURING MFG OR ACCOMPLISHMENT OF MFG''S SB. SUSPECT THE COAT SEPARATED DUE TO ITS EXCESSIVE LENGTH (2.1250 INCHES) WHICH COVERS AN AREA OF FASTER AIRFLOW AND IS DIFFERENT FROM MFG''S SPEC LENGTH OF .50 TO .75 INCH. THE CONDITION IS NOT NORMALLY INSPECTED DURING SCHEDULED MAINT UNLESS RAFT FAILS FUNCTIONAL TEST. REF: HOOVER INDUSTRIES SB 4600-25-01. (X)