What was found
FOUND DURING D-CHECK, C PIT STATION 1060 L36 CORROSION ON CIRCUMFERENTIAL FRAME. REMOVED CORROSION IAW DC-8 SRM 51-1-8. FABRICATED NEW FRAME AND DOUBLERS FOR SPLICE IAW DC-8 SRM 51-1-4. TREATED, PRIMED AND INSTALLED IAW DC-8 SRM 51-1-8, 51-1-20D AND EO NR 99-186 WITH APPROVED 8110-3 DATED 12/09/99. (M)