SAW - DURING CPCP-2 INSPECTION, FOUND FLOORBEAMS 36, 38, 39 AND 40 CORRODED BEYOND LIMITS. REMOVED AND REPLACED CORRODED FLOORBEAMS 36 AND 38 IAW SRM 51-25-01. REPAIRED FLOORBEAMS 39 AND 40 IAW SRM 53-61-40. (M)