As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABLE PARTED .25 INCH AFT OF MS20668-3 SWAGED TERMINAL EYE END FITTING, IN AN AREA VERY DIFFICULT TO INSPECT VISUALLY, CAUSING SUDDEN FLAP RETRACTION. SUBMITTER RECOMMENDED PERIODIC INSPECTION EVEN IF IT REQUIRES REMOVAL OF THE CABLE. SUBMITTER STATED DESIGN OF INSTALLATION MAY CAUSE BEND IN CABLE IMMEDIATELY ADJACENT TO RIGID END FITTING. (X)