What was found
DURING FLIGHT, PILOT NOTICED RIGHT LANDING LIGHT CIRCUIT BREAKER OPEN. AFTER LANDING, INSP FOUND LEFT TIP TANK FUEL TRANSFER PUMP P/N 476411 FAILED ELECTRICALLY. PUMP SHOWED SIGNS OF HEAT AND ARCING ON OUTSIDE OF CASE FROM INTERNAL FAILURE. THIS PUMP IS WIRED BY MFG THROUGH LANDING LIGHT CIRCUIT. SUBMITTER STATED THESE PUMPS HAVE HAD A HIGH FAILURE RATE. THE PUMP ON THIS AIRCRAFT IS THE THIRD ONE INSTALLED IN 10 MONTHS. TIME BETWEEN FAILURES HAS BEEN 48 HRS, 10.3 HRS, 95.7 HRS. PUMP IS REQUIRED EQUIPMENT FOR AD NOTE MANDATED EQUIPMENT ON ALL SUCH INSTALLATIONS AND IS REQUIRED FOR FLIGHT OPERATIONS. ELECTRICAL FAILURE OF FUEL PUMPS CONSTITUTES A SIGNIFICANT FIRE/EXPLOSION HAZARD. (X)