What was found
AUS-SJC - THE EQUIPMENT BAY OVERHEAT LIGHT ILLUMINATED. THE CHECKLIST WAS RUN AND THE LIGHT WAS EXTINGUISHED WITH THE NR 1 AIR VALVE IN HP AND THE NR 2 IN LP. THE AIRCRAFT LANDED AT SJC WITHOUT INCIDENT. AN INSPECTION OF THE REAR BAY SHOWED NO SIGN OF OVERHEATING. WITH BOTH ENGINES RUNNING, A SMALL LEAK WAS DETECTED AT A CLAMP SEAL ON THE FLOW CONTROL VALVE. THE JOINT WAS RESEALED AND A SECOND GROUND RUN WAS PERFORMED, NO LEAKAGE NOTED. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)