What was found
CYLINDER NR 2 REMOVED FOR LOW COMPRESSION DUE TO LEAKAGE PAST THE INTAKE VALVE. THE REPAIR STATION THAT REPAIRED THE CYLINDER ASSEMBLY REPLACED THE INTAKE AND EXHAUST VALVES, EXHAUST GUIDE, AND ASSOCIATED PARTS. THE INTAKE VALVE''S FACE WAS CUPPED, EXHAUST VALVE WAS STRETCHED .0045 INCH, AND THE EXHAUST VALVE GUIDE WAS WORN OVERSIZED. (X).