What was found
NYLON DRIVE GEAR WORN AND DECOMPOSED DUE TO WATERY CHEMICAL WITHIN MAGNETO CASE. COULD HAVE BEEN CAUSED BY A PRESSURE WASHER AFTER AN OIL CHANGE OR OTHER SERVICE OR MAINTENANCE. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NYLON DRIVE GEAR WORN AND DECOMPOSED DUE TO WATERY CHEMICAL WITHIN MAGNETO CASE. COULD HAVE BEEN CAUSED BY A PRESSURE WASHER AFTER AN OIL CHANGE OR OTHER SERVICE OR MAINTENANCE. (X)