As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HYDRAULIC SYSTEM A PRESSURE AND QUANTITY ZERO. ENGINES 1 AND 3 PUMPS LIGHTS ON APPROXIMATELY 5 MINUTES AFTER ELEVATOR FEEL DIFFERENTIAL PRESSURE LIGHT ON. CONTINUED TO DESTINATION. *S/D* FOUND ELEVATOR HYDRAULIC BYPASS VALVE ASSEMBLY DAMAGED AND LEAKING. REPLACED MODULE. OPERATIONAL AND LEAK CHECKED NORMAL.